Recent Changes

Tuesday, November 8

  1. page 10 Foundations edited Chase Stanley 0890792 Foundation system: concrete grade beams with caissons Grade beams are to …
    Chase Stanley 0890792
    Foundation system: concrete grade beams with caissons
    Grade beams are to support the double concrete walls seen on page "08 primary..."
    (view changes)
    11:11 pm
  2. page 09 Tributary Load edited Chase Stanley 0890792 Below is a screen shot of a spread sheet I created for calculating live l…
    Chase Stanley 0890792
    Below is a screen shot of a spread sheet I created
    for calculating live loads according to my building's
    (view changes)
    11:10 pm
  3. page 08 Primary & Secondary Structure edited Chase Stanley 0890792 Sequence drawings with legend at bottom (to be updated): {1.png} Foundati…
    Chase Stanley 0890792
    Sequence drawings with legend at bottom (to be updated):
    {1.png} Foundation
    (view changes)
    11:10 pm
  4. page 07 HVAC schematic design edited Chase Stanley 0890792 Approximate Space Sizes: All figures derived from Tables 10.3 & 10.4 …
    Chase Stanley 0890792
    Approximate Space Sizes:
    All figures derived from Tables 10.3 & 10.4 in MEEB
    (view changes)
    11:10 pm
  5. page 06 Spatial Organization edited Chase Stanley 0890792 The zoning and spatial organization is broken up into four main categories…
    Chase Stanley 0890792
    The zoning and spatial organization is broken up into four main categories of the program seen in the color coded legend below.
    ...
    street atmosphere.
    The

    The
    support spaces
    ...
    back, against
    the 8 story building because these spaces require the least amount of daylighting. The dining is raised up to the second and third floors
    to isolate them from the noise at street level, and to provide better views of Market Square. The Theaters are also on the second and third
    (view changes)
    11:09 pm
  6. page 05 Noise Control edited Chase Stanley 0890792 Because I have two smaller theaters that are stacked (one on the second fl…
    Chase Stanley 0890792
    Because I have two smaller theaters that are stacked (one on the second floor, and one on the third floor directly above),
    ...
    want sound
    interference

    interference
    happening between
    ...
    theaters simultaneously.
    {Screen_Shot_2011-11-04_at_6.10.40_AM.png}
    (view changes)
    11:09 pm
  7. page 04 Room Acoustics edited Chase Stanley 0890792 LOOKING at CIRCULAR THEATRE SPACE ONLY From the chart below, I figured th…
    Chase Stanley 0890792
    LOOKING at CIRCULAR THEATRE SPACE ONLY
    From the chart below, I figured that the optimum reverberation time for small theaters is between 1.2-1.4, and that the
    (view changes)
    11:09 pm
  8. page 03 Artificial Lighting edited Below Chase Stanley 0890792 Below are screen ... Spreadsheet calculations. I chose a LED T…
    BelowChase Stanley 0890792
    Below
    are screen
    ...
    Spreadsheet calculations.
    I chose a LED Troffer lamp and chose to evaluate my interior dining space.
    ZONAL CAVITY LIGHTING:
    (view changes)
    11:08 pm
  9. page 02 Daylighting Design edited _ Chase Chase Stanley 0890792 According to Climate Consultant, the annual light level in foot-c…
    _ ChaseChase Stanley 0890792
    According to Climate Consultant, the annual light level in foot-candles:
    {Screen_Shot_2011-11-04_at_2.59.20_AM.png}
    (view changes)
    11:08 pm
  10. page 02 Daylighting Design edited _ Chase Stanley 0890792 According to Climate Consultant, the annual light level in foot-candles:…
    _ Chase Stanley 0890792
    According to Climate Consultant, the annual light level in foot-candles:
    {Screen_Shot_2011-11-04_at_2.59.20_AM.png}
    (view changes)
    11:07 pm

More